For replacement parts, contact the distributor from which the dryer
was purchased or
Continental Girbau, Inc.
®
2500 State Road 44
Oshkosh WI 54904
Telephone: (920) 231-8222 / Fax: (920) 231-4666
www.cont-girbau.com
022003JEV/mcronan CGI Part No. A113172
CG75-85
(Gas DSI/Electric/Steam Phase 7 with S.A.F.E.
and Dual Timer/1,000 cfm)
Installation Manual
WARNING: For your safety the information in
this manual must be followed to minimize the
risk of fire or explosion or to prevent property
damage, personal injury or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Clear the room, building or area of all
occupants.
Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette notice
pour réduire au minimum le risque d’incendie
ou d’explosion ou pour éviter tout dommage
matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables à
proximité de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
Ne pas tenter d’allumer d’appareils.
Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones se trouvant dans
le bâtiment.
Évacuez la pièce, le bâtiment ou la zone.
Appelez immédiatement votre fournisseur
de gaz depuis un voisin. Suivez les
instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
Vue de la page 0
1 2 3 4 5 6 ... 59 60

Résumé du contenu

Page 1 - Installation Manual

For replacement parts, contact the distributor from which the dryerwas purchased orContinental Girbau, Inc.®2500 State Road 44Oshkosh WI 54904Telephon

Page 2 - Important

6SECTION IISPECIFICATIONS/COMPONENT IDENTIFICATIONA. SPECIFICATIONSShaded areas are stated in metric equivalents* ALL CG75-85 reversing dryers are su

Page 3 - FOR YOUR SAFETY

7SpecificationsCG75-85(Gas/Electric/Steam)NOTE: The manufacturer reserves the right to make changes in specifications at any time withoutnotice or obl

Page 4

8B. COMPONENT IDENTIFICATION1. Dryer Front ViewIllus. No. Description1 Controls2 Control (top access) Door Assembly3 Main Door Assembly4 Lint Compart

Page 5 - Table of Contents

92. Dryer Rear ViewIllus. No. Description1 Heating Unit2 Electric Service Relay Box3 Basket (tumbler) Bearing Mount Assembly4 Idler Bearing Mount Asse

Page 6

10SECTION IIIINSTALLATION PROCEDURESInstallation should be performed by competent technicians in accordance with local and state codes. In theabsence

Page 7 - SECTION I

11B. UNPACKING/SETTING UPRemove protective shipping material (i.e., plastic wrap and/or optional shipping box) from dryer.IMPORTANT: Dryer must be tr

Page 8 - B. SAFETY PRECAUTIONS

12C. DRYER ENCLOSURE REQUIREMENTSBulkheads and partitions should be made of noncombustible materials and must be located a minimum of12-inches (30.4

Page 9

13D. FRESH AIR SUPPLY REQUIREMENTSWhen the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), andexhau

Page 10 - SECTION II

14E. EXHAUST REQUIREMENTS1. General Exhaust Ductwork InformationExhaust ductwork should be designed and installed by a qualified professional. Impro

Page 11 - (Gas/Electric/Steam)

15IMPORTANT: Exhaust back pressure measured by a manometer in the exhaust duct must be no lessthan 0 and must not exceed 0.3 inches (0.74 mb) of water

Page 12 - B. COMPONENT IDENTIFICATION

Retain This Manual In A Safe Place For Future ReferenceThis product embodies advanced concepts in engineering, design, and safety. If this product is

Page 13

16IMPORTANT: For extended ductwork runs, the cross section area of the ductwork can only beincreased to an extent. When the ductwork approaches the m

Page 14 - SECTION III

173. Multiple (Common) Dryer VentingIMPORTANT: For extended ductwork runs, the cross section area of the ductwork can only beincreased to an extent.

Page 15 - B. UNPACKING/SETTING UP

18IMPORTANT VENTING REMINDERS1. Ductwork size and installation should be done by a qualified professional.2. The dryer must be exhausted to the outdoo

Page 16

19F. ELECTRICAL INFORMATION1. Electrical RequirementsIt is your responsibility to have ALL electrical connections made by a properly licensed and com

Page 17

202) Electric Models OnlyALL electrically heated dryers must be connected to the electric service shown on the dryer’sdata label, which is affixed to

Page 18 - E. EXHAUST REQUIREMENTS

21SINGLE-PHASE (1Ø) ELECTRICAL CONNECTIONS LEADSBlack+WhiteWhite-NeutralGreenGroundorL2If local codes permit, power to the dryer can be made by th

Page 19

225. 3-Phase (3ø) Wiring Connections/Hookup (For Non-Reversing Models Only)The only electrical input connections to the dryer are the 3-phase (3ø) pow

Page 20

236. 3-Phase (3ø) Wiring Connections/Hookup (for Reversing Models Only)The electrical connections on ALL 3-phase (3ø) gas dryers and steam dryers are

Page 21

24CAUTION: The dryer must be grounded. A ground lug has been provided for this purpose.IMPORTANT: A CIRCUIT SERVICING EACH DRYER MUST BE PROVIDED.The

Page 22 - IMPORTANT VENTING REMINDERS

25IMPORTANT: Figures shown are for non-reversing models only. For reversing models contactContinental Girbau, Inc.®IMPORTANT: The dryer must be conne

Page 23 - F. ELECTRICAL INFORMATION

IMPORTANTYOU MUST DISCONTINUE AND LOCKOUT THE ELECTRIC SUPPLY AND THE GASSUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS AREREMOVED FROM THE MA

Page 24

26G. GAS INFORMATIONIt is your responsibility to have ALL plumbing connections made by a qualified professional to assure that thegas plumbing instal

Page 25

272. Technical Gas Dataa. Gas Specificationsb. Gas Connections:Inlet connection --------------3/4” N.P.T.Inlet supply size --------------3/4” N.P.T. (

Page 26

283. Piping/ConnectionsALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATESTEDITION, or in Canada, CAN/CGA

Page 27

29Consistent gas pressure is essential at ALL gas connections. It is recommended that a 3/4-inch (19.05mm) pipe gas loop be installed in the supply l

Page 28

30H. STEAM INFORMATIONIt is your responsibility to have ALL plumbing connections made by a qualified professional to assure that thesteam plumbing in

Page 29 - CG75-85 (GAS/STEAM)

31IMPORTANT: Steam coil failure due to water hammer by wet steam will VOID THE WARRANTY.a. The pressure of the condensate in the steam supply will cau

Page 30 - G. GAS INFORMATION

324. Steam Damper Air System ConnectionsSteam models are manufactured with a pneumatic (piston) damper system, which requires an externalsupply of com

Page 31 - TYPE OF GAS

33c. Air RegulationNo air regulator or filtration is provided with the dryer. External regulation/filtration of 80 PSI (5.51 bar)must be provided. I

Page 32

346. Steam Damper Air Piston (Flow Control) Operation AdjustmentDamper operation was tested and adjusted prior to shipping at 80 PSI (5.51 bar). If d

Page 33

35I. PREPARATION FOR OPERATION/START-UPThe following items should be checked before attempting to operate the dryer:1. Read ALL “CAUTION,” “WARNING,”

Page 34 - OPERATING STEAM PRESSURE

WARNINGThe dryer must never be operated with any of the back guards, outer tops, or servicepanels removed. PERSONAL INJURY OR FIRE COULD RESULT.IMPOR

Page 35

36J. PREOPERATIONAL TESTSALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational testshould be performe

Page 36 - 4.83 bar

37NOTE: To check for proper sail switch operation (for gas and electric models only), open the maindoor and while holding main door switch plunger in,

Page 37 - Diagram 2

38K. PREOPERATIONAL INSTRUCTIONSOPL MODELS1. To start the dryer:a. Microprocessor controller (computer) dryers...1) Light emitting diode (L.E.D.) dis

Page 38

39SECTION IVSERVICE/PARTS INFORMATIONA. SERVICE1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If s

Page 39

40SECTION VWARRANTY INFORMATIONA. WARRANTYFor a copy of the manufacturer’s commercial warranty bond covering your particular dryer(s), contact thedis

Page 40 - J. PREOPERATIONAL TESTS

41SECTION VIROUTINE MAINTENANCEA. CLEANINGA program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from

Page 41

42WARNING: When cleaning steam coil fins, be careful not to bend the fins. If fins are bent, straightenby using a fin comb, which is available from l

Page 42 - L. SHUTDOWN INSTRUCTIONS

43D. LINT DRAWER REMOVALTo remove the lint drawer from the dryer pull drawer out approximately halfway. Rotate/move lint drawer stophinge (refer to

Page 43 - SECTION IV

44SECTION VIIDATA LABEL INFORMATIONA. DATA LABELWhen contacting Continental Girbau, Inc.® certain information is required to insure proper service/p

Page 44 - SECTION V

45THE DATA LABEL1. MODEL NUMBERThe model number is a manufacturer’s number, which describes the size of the dryerand the type of heat (gas, electric,

Page 45 - SECTION VI

Table of ContentsSECTION IIMPORTANT INFORMATION ... 3A. Receiving and Hand

Page 46 - C. LUBRICATION

46SECTION VIIIREVERSING TIMER SPIN/DWELL ADJUSTMENTSDual timer models with “reversing option” have an electric reversing timer in the electric service

Page 47 - D. LINT DRAWER REMOVAL

47SECTION IXPROCEDURE FOR FUNCTIONAL CHECKOF REPLACEMENT COMPONENTS1. Microprocessor Controller (Computer) Boarda. Upon completing installation of the

Page 48 - SECTION VII

482. For Models With Johnson Controls Direct Spark Ignition (DSI) Module (G760)Theory Of Operation:Start the drying cycle. When the gas burner ignite

Page 49 - THE DATA LABEL

49The exclusive Sensor Activated Fire Extinguishing (S.A.F.E.) System will extinguish firesthat may start in the drying basket (tumbler). A series of

Page 50 - SECTION VIII

50BEFORE YOU START!CHECK LOCAL CODES AND PERMITSCall your local water company or the proper municipal authority for information regarding local codes.

Page 51 - SECTION IX

512. Water Connections:The water connection is made to the 1/2” M.P.T.bushing of the electric water solenoid valve locatedat the rear upper left area

Page 52

52OPTIONAL MANUAL BYPASSProvisions are made in the dryer sensor activated fire extinguishing (S.A.F.E.) system for the installation of anoptional manu

Page 53 - S.A.F.E. System In Action

53Sensor ActivatedFire Extinguishing (S.A.F.E.) SystemTheory of OperationWhile the dryer is in an idle state or 20-seconds after the heat turns off, t

Page 54 - INSTALLATION

54Sensor ActivatedFire Extinguishing (S.A.F.E.) SystemParts Break DownReplacement parts can be obtained from your reseller or the ADC factory. When o

Page 55 - Typical water supply

55Illus. No. Part No. Qty. Description1 822752 1 Sensor Activated Fire Extinguishing (S.A.F.E.) System Temperature ProbeAssembly(includes illus. nos.

Page 56

SECTION VIROUTINE MAINTENANCE ...41A. Cleaning ...

Page 57 - Theory of Operation

CGI 113172 1 - 02/21/03-25

Page 58 - Parts Break Down

3SECTION IIMPORTANT INFORMATIONA. RECEIVING AND HANDLINGThe dryer is shipped in a protective stretch wrap cover with protective cardboard corners and

Page 59

4B. SAFETY PRECAUTIONSWARNING: For your safety, the information in this manual must be followed to minimize the risk offire or explosion or to preven

Page 60 - CGI 113172 1 - 02/21/03-25

57. A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork,and area around the back of the dryer

Commentaires sur ces manuels